Tuesday, January 11, 2011
【 Weak current College 】 markets fire safety management measures---Power By 【 China power house network 】
【 Timeliness 】 effective
【 Statute name】 markets fire safety management measures
【 Regulatory classification 】 Administration for industry and Commerce
【 Promulgated sector 】 Ministry/SAIC
【 Promulgation date 】 19941225
【 Implementation date 】 19941225
【 Body 】 People's Republic of China State administration for industry and Commerce of the Ministry of public security, order No. 19 markets fire safety management measures Chapter 1 General provisions article 1 in order to strengthen the bazaars of fire safety management, prevention and reduction of the incidence of fire, the fire under the People's Republic of China and its implementing rules and regulations. Article 2: this method is called bazaars, refers to the Administrative Department for industry and Commerce for registration of the following market agricultural products market, daily-use industrial goods market and integrated market: (a) building area of 1000 square meters or more than 100 booths indoor market; (ii) covers an area of 1000 square meters or more than 200 stalls in outdoor markets; (iii) in the market within underground building. Other markets combined with local references. Third country markets is strictly business inflammable. Article IV of the fire safety work markets by the organiser is responsible for the industrial and commercial administration help, fire supervision agencies exercising supervision. Chapter 2, article 5 of the fire-fighting organization Fairs Organizer shall establish the fire management branch; multiple jointly chargehand should be established relating to participate in the governing bodies of the fire, the unified management of fire safety work. Article VI of the principal markets for the market of fire. Its main function is to: (a) and participation in market operations unit and the individual signing the doucument of fire safety; (ii) organize fire safety education, to develop the use of fire power and other fire prevention management system; (3) fire personnel fire fire hazards, the rectification, to develop an emergency evacuation plan; (4) establishing full-time, obligations to develop plans for fire-brigade, fire-fighting drills; (5) is responsible for market fire and fire-fighting equipment configuration; (6) organization fighting early fire and evacuation, protection of the scene of the fire. 7 various markets should establish obligations for the fire brigade. These markets should be equipped with dedicated fire officer: (a) building area 10000 square meters or stalls over 1000 indoor markets; (ii) 10000 m2 above or booth 2000 more outdoor markets; (iii) a building area of 1000 square meters or more than 100 booths underground markets. Size is less than the market in other markets, established part-time fire personnel, conditions can be set up dedicated fire personnel. Article 8 the following daily industrial market and integrated markets, should establish informal professional fire brigade. 1 difficult to have the conditions, it shall take provisional emergency measures effectively. (A) building area 20000 square meters or more than 2000 booth indoor market; (ii) 20000 m2 above or pitch 4000 more outdoor markets; (iii) a building area of 2000 square meters or more than 200 booths underground market. 9 fairs in fire safety should be put on duty and patrol inspection system. Article 10 markets, various types of personnel, should be organized or co-organized the market fire safety management, the stall were to receive fire safety education and training, voluntary fire service organizations and the obligation to put out the fire. Chapter III building fire management 11 all new, expanded and reconstructed and interior decoration of the markets, their design must comply with the national technical specifications relating to the fire, and reported to the local public security and fire fighting supervisory body for approval. After the completion of the project, must pass through the fire monitoring body acceptance before use. Organizers and managers need to change the nature of architectural patterns or use, you should first reported to the local public security fire fighting supervisory body approval. Article 12 where in town building outdoor markets, sponsors or joint units shall, prior to its location and occupation, reported to the local public security fire supervision agencies implement fire safety audit. Article 13, outdoor structures of markets should be made of non-combustible roof it or nonflammable materials. Article 14 outdoor markets must not be blocked fire channel and impact of the use of public fire protection facilities; and, b the fire risk in workshops, warehouses and flammable, combustible material yard to maintain 50 meters above the safe distance. Article 15, under the high-voltage outdoor markets in 5 meters on both sides, not stall point setting. Article 16 the markets according to the type of goods and the fire risk, is divided between a number of areas, the region remains the appropriate evacuation channels. Chapter IV used fire electricity fire management 17 markets in non-Fireworks and burning items. In designated areas or strictly forbidden to smoke, you should set the visible region of the smoking ban fire signs. 18 markets in the electrical lines and electrical devices, must comply with the national electrical-design, installation specifications. Article 19 within operators in markets with the electrical wiring and electrical devices, must be unified by the organizers commissioned pre-qualified construction units and holds a certificate of conformity of the electrical charge of the installation, inspection and maintenance. Prohibited individuals pulling set TEMP line. Article 20 business lighting electricity markets, should be the driving force, fire power separate settings. Article 21 sets of outdoor markets should not be forbidden, high temperature and lighting. Article 22 within the power switch of the Mall, outlet, etc., should be installed in a closed distribution box. Distribution box should use non-burning material. Chapter 5: equipment for fire-fighting facilities, equipment and management of article 23 of the fairs Hall, offices, warehouses and other rooms shall be in accordance with the State of the construction of fire extinguishers configuration design specifications ", jointly organised by the host or unit is responsible for fire-fighting equipment equipped. Article 24 markets building fixed fire-fighting facilities, repair and maintenanceThe unit is responsible for the markets property. Article 25 full-time or obligation necessary for fire fire brigade equipment, from the Bazaar organizers. 26 the pitch should be organised or co-organised by the market organization, configure the appropriate fire-fighting equipment, and learn how to use it. Article 27 the public fire facilities, equipment, it should be clear and easy to decorate the venue, clearly drawn by hand. No person shall use a public fire hydrant ring into the booth. Article 28 markets should be equipped with the basic communication and alarm device, in the event of an alarm of fire can be done in a timely manner. Chapter 6, article 29 on rewards and punishment in the fire-fighting work achievement of units and personal hosting by market or joint units, industrial and commercial administration and fire monitoring bodies to recognize and incentives. Article 30 provisions contrary to this approach, in accordance with relevant legislation be punished; the Constitution crime, legally investigates the legal responsibility. Chapter 7 supplementary provisions of article 31 of this approach by the Ministry of public security and the joint responsibility of the State administration for industry and commerce. Article 32 of this approach on the day of its promulgation.
Labels:
[:]
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment