Wednesday, January 26, 2011

【 Weak current College 】 fire-places--banks, securities exchange of fire-Power By 【 China power house network 】


The Bank is an important part of the financial undertaking, under conditions of market economy, the Bank developed very rapidly, Bank Treasury and Bank's vital parts, do a Treasury of fire prevention is extremely important. 1. fire risk 1. at present, China's southern cities, many of the new Bank is a high-rise building, complex functions, saving many located in underground construction, in the event of fire, it is difficult to find, difficult to extinguish; original bank you are with other construction phase of the adjoining or attached in other buildings, not separated, or fire-brick, fire resistance ratings are also low, potential fire hazard. 2. electrical equipment in addition to electrical line lighting, due South, rainy, humid summer air, many with dehumidifiers, air conditioners, and other electrical devices, such as installation, improper use, load fever, will cause a fire. 3. Treasury stocks of many is in the notes and Treasury in large numbers into notes, some also with combustible materials packaging, such as control, will be brought into the fire. 4. incorporating some savings in other buildings, its architecture and decoration material does not meet the requirements of the fire resistance rating, coupled with the lack of fire-fighting equipment, also has certain fire risk. 5. Management, external access, lack of strict registration and approval system, and some workers ' safety awareness among, and cause fire. 2. fire prevention measures 1. located in high-rise buildings and underground construction of the Treasury, should follow the book the first episode of the senior civil building design fire protection standard "and the" architectural design fire protection standard of requirements for implementation. Its architectural fireproof grade must be level. Because Treasury is a special key parts, Treasury and other construction phase the contiguous, and must be separated by a firewall, the firewall should not be opened doors and Windows. If you have to offer, you should use class a fire door, and be able to close. Interior decoration materials (including racks, etc.) should be the use of combustible materials. 2. on a dehumidifier, air conditioners, there should be regular boot, the boot-time to be left to leave time to cut off the power. In lighting, air conditioners, dehumidifiers, and layout of line respectively. Control switch must be located outside the library. 3. installation line, wire insulation strength should not be lower than the rated voltage, armoured cable or metal pipe sleeve copper heart line concealed within the lighting, the library must be closed. 4. installation line, wire connector firmly. At the same time, to prevent the knife, clamp or casing when scratched wire insulation. In addition, you should install a suitable circuit breaker to electrical failure can automatically cut off power supply. Usually have to step up checks and maintenance to find problems in a timely manner. 5. Treasury in addition equipped with a fire hydrant and corresponding fire equipment within the library should have automatic fire alarm systems and automatic fire extinguishing system. Conditional can also be installed CCTV cameras. 6. the management personnel should adhere strictly to the Treasury regulations of fire is strictly forbidden. Non-Treasury managers must enter the National Treasury, must be provided for approval, registration, and shall not be brought into a handbag. Lighters and other items. Treasury to implement 24-hour double duty system. 7. the Bank's business premises, securities exchange of fire can refer to the "shopping centre in the language of the fire protection requirements for fire", the place of computers, computer room, you can reference in the "computer language and its facilities of fire".

No comments:

Post a Comment