Saturday, January 22, 2011

【 Weak current College 】 3 c certification and type approval fire product catalog---Power By 【 China power house network 】


According to the Ministry of public security, AQSIQ <关于加强消防产品质量监督管理工作的通知> (gongtong Word 【 2003 】 38, 20 October) file provided by the Ministry of public security and national accreditation authority, fire product 3 c certification and type approval by the Ministry of public security fire product conformity assessment Center. Other fire fighting products and fire-related products for mandatory inspection system, and by the appropriate national level of fire protection products quality inspection center. For the convenience of fire products production, sales, use, monitoring, and other units and individual query, the Ministry of public security and national accreditation approved current 3 c certification of fire protection products directory and type approval of fire product directory. The Ministry of public security fire product conformity assessment Center 2003 June 13 3 c certification of fire protection products directory first, mandatory fire alarm products certified products directory and certification unit Division serial number name Unit Division principles certification according to the standard master sent samples of number 1 fire alarm controller fire alarm controller principle each model products into a request unit, but the following conditions of product, its classification of products and their main products as an application unit: 1. Alarm circuit number reduced and resulting mechanical dimensions and power capacity; 2. Alarm output or control output circuit number reduced and resulting mechanical dimensions and power capacity; 3. Panel layout design; 4. Other not on product performance impacts of small differences. GB4717 — 93 main product: 3/each model type product: 3/2 points for each model type smoke detector point-smoke detector in principle each model products into a request unit, but the following conditions of product, its classification of products and their main products as an application unit: 1. Base form; 2. Classification of the product does not have driven peripherals led circuit or Terminal; 3. Classification of products do not have address coding circuit; 4. Classification of the product has the waterproof, anti-mildew property; 5. Sensitivity levels are different; 6. Other not on product performance impacts of small differences. GB4715 — 93 main products: 22 å/each model type product: 6/each model
Ordinal name Unit Division principles certification according to the standard master sent samples of number 3 point-type heat fire detectors-point temperature sensor detector principle each model products into a request unit, but the following conditions of product, its classification of products and their main products as an application unit: 1. Base form; 2. Classification of the product does not have driven peripherals led circuit or Terminal; 3. Classification of products do not have address coding circuit; 4. Classification of the product has the waterproof, anti-mildew property; 5. Sensitivity levels are different; 6. Other not on product performance impacts of small differences. GB4716 — 93 main products: 22 å/each model type product: 6/4 each model fire control equipment fire control equipment is, in principle, each model products into a request unit, but the following conditions of product, its classification of products and their main products as an application unit: alarm circuit number reduced and resulting mechanical dimensions and power capacity; alert output or control output circuit number reduced and resulting mechanical dimensions and power capacity; Panel layout design; others do not have an impact on the performance of the small differences. GB16806 — 1997 main products: 2 sets per model classification: 1/each model
Ordinal name Unit Division principles certification according to the standard master sent samples of number 5 manual fire alarm button for manual fire alarm button, in principle, each model products into a request unit, but the following conditions of product, its classification of products and their main products as an application unit: 1. Classification of products do not have address coding circuit; 2. Classification of the product has the waterproof, anti-mildew property; 3. Other not on product performance impacts of small differences. GA5 — 91 main product: 14/each model type products: 4/each model II fire hose products mandatory certification product catalog and certification unit Division serial number name Unit Division principles certification according to the standard master sent samples of number 1 with fire hose 1. According to the type of the products; the same weaving layer different lining materials separate from the application of the product; the same lining materials different from braid's products. GB6246 — 2001 taking applications for the longest length unit specifications sample: 3 root 2 fire wet zone 1. Press model application; 2. Same weaving layer different lining materials separate from the application of the product; the same lining materials different from braid's products. GA34-92 by applying the longest length unit specifications sample: 3 three, automatic sprinkler systems product mandatory certification product catalog and certification unit Division serial number name Unit Division principles certification according to the standard master sent samples of number 1 sprinkler type products to their primary product as an application for the same temperature unit: action, glass ball diameter different applications cannot be used as a unit; 3. Nominal diameter, you cannot apply as a unit. 93 pick GB5135 — apply for any of the specifications in the cell as the main type of samples: 130 only (glass ball 60 only); 2. For classification of products, the same material, the same production process, the same nominal diameter of different nominal action temperature samples: 70 only (glass ball 60 only); the same nominal action temperature, process, materials, same, different types of samples: 50 only; 3. When sampling, extraction and the same number of samples to send reserve samples. 2 wet alarm valve type products to their primary product as an application unit: 2. Nominal diameter is the same, structure, you cannot apply as a unit. Application by GB797 — 89 units either nominal diameter as the primary product samples: 2; 2. Other specifications as parting product samples: 1; 3. When sampling, extraction and the same number of samples to send reserve samples. 3 flow meansAs for typing of products to their primary product as an application unit: 2. Structure and installation of the form, you cannot apply as a unit. Application by GA32-92 in any of the specifications as the primary type of sample products: 4; 2. Other specifications as parting product samples: 2; 3. When sampling, extraction and the same number of samples to send reserve samples. 4 pressure switch typing products to their primary product as an application module for fetching GA29-92 in any of the specifications as the primary product samples: 6;; 2. Other specifications as parting product samples: 3; 3. When sampling, extraction and the same number of samples to send reserve samples.
The Ministry of public security fire product conformity assessment center type approval fire product catalog (2005 update) the ordinal number of the product category name to perform a standard note 1 medium protein, f protein foam extinguishants GA219-1999 GB17835-1999 aqueous film forming foam extinguishing agent GB17427-1998 anti foam extinguishing agent GB13463-92 high, medium, low foam extinguishing agent GB15038-94BC GB4066.1-2004ABC powder extinguishing agent extinguishing GB4066.2-2004 dioxide GB4396-84 difluoride a chlorine methyl bromide extinguishant GB4065-83 f a methyl bromide extinguishant GB6051-852 fire door grade a steel fire doors GB12955-91 grade b steel fire doors c steel fire doors-wooden fire door GB14101-93 b wooden fire door c wooden fire door 3 fire hydrant GB3445-93 aboveground fire hydrant GB4452-1996 underground fire hydrant aboveground fire pump adapter GB3446-93 underground fire pump adapter wall-fire pump adapter more use-fire pump adapter 4 fire extinguisher hand-held sodium bicarbonate dry chemical fire extinguisher GB4351-1997 hand-held portable extinguishers ammonium salt extinguisher ordinal product category name to perform a standard note 4 foam fire extinguishers, fire extinguisher hand-held machinery GB4351-1997 hand-held portable fire extinguishers in the Shui-1211 fire extinguishers trolley sodium bicarbonate dry chemical fire extinguisher GB8109-87 trolley-ammonium phosphate powder fire extinguisher trolley carbon dioxide fire extinguishers stroller style mechanical foam fire extinguishers trolley type water-type fire extinguishers trolley-1211 fire extinguishers and fire hose 5 interface interface GB12514-90GB3265-1995 Canal interface fixed interface reducing interface profiled interface suction pipe interface 6 fire guns DC gun GB8181-87 DC switch gun DC fire fog nozzle 7 fitting fire emergency lighting GB17945-20008 fire alarm equipment combustible gas alarm controller GB16808-1997 combustible gas detector-part 1: measurement range from 0 ~ 100% LEL's point-combustible gas detector GB15322.1-2003 combustible gas detector-part 2: measurement range from 0 ~ 100% LEL freestanding combustible gas detector GB15322.2-2003 combustible gas detector-part 3: measuring range is from 0 ~ 100% LEL portable combustible gas detector GB15322.3-20038 fire alarm equipment combustible gas detector-part 4: measurement of manufactured gas point of combustible gas detector GB15322.4-2003 combustible gas detector-part 5: measurement of manufactured gas in freestanding combustible gas detector GB15322.5-2003 combustible gas detector-part 6: measuring artificial gas portable combustible gas detector GB15322.6-20039 fireproof materials fire retardant coatings for steel structures GB14907-2002 decorative fireproof coatings GB12441-1998 cable fire-retardant coatings GA181-1998 inorganic fire blocking GA161-1997 organic fire blocking flame package

No comments:

Post a Comment