Saturday, December 18, 2010

【 Weak current College 】 port the fire planning and construction management regulations---Power By 【 China power house network 】


【 Timeliness 】 effective
【 Statute name】 port the fire planning and construction management provisions
【 Regulatory classification 】 traffic laws
【 Promulgated sector 】 Ministry
【 Promulgation date 】 19920306
【 Implementation date 】 19920501
【 Body 】 turn of public security issued (1992), no. 151, port the fire planning and construction management provisions of Chapter 1 General provisions article 1 in order to protect the port security, fire under the People's Republic of China and its implementing rules and supervision of the port the fire, to develop measures for the implementation of this regulation. Article 2 this Regulation applies to port new, alteration, extension project planning, construction of fire. Article 3, the port the fire facilities and port construction planning, design, unity-building unity, unified principles of acceptance. Article 4 of the port the fire building planning must be included in the overall planning of ports, by port firefighting supervisory authority audit and report to the superior fire monitoring authority record. 5 port firefighting supervisory bodies in accordance with the technical specifications relating to fire on the port construction engineering conduct fire design audit, inspection and acceptance of fire-fighting facilities. 6 port the fire facility construction, management and usage, as enterprise assessment, appraisal, promotion of a piece of content. Article 7 of this regulation by the port planning, planning, infrastructure, communications and water supply, power supply and other relevant departments implement the port firefighting supervisory authority responsible for supervision. Chapter II general layout of the port the fire requirements of article 8 of the overall layout of the port, you must set the storage, loading and unloading of dangerous goods, as well as Terminal, warehouse ships carriage class anchorage located in a relatively independent safety. Port area has been completed, does not comply with the relevant provisions of the fire technical specifications and the dangerous cargo berths, warehouses, anchorages, etc., must be incorporated into the reconstruction plan, migrate or change the nature of the measures used to eliminate unsafe. 9 port planning, construction, and reasonable choice of LPG stations, gas stations, with (variable) power station, painting Gallery, acetylene gas, oxygen cylinder library, boiler room and transport flammable liquids, flammable gas pipeline location, set clear fire signs. Prohibited in their fire separation within the structures of any building, structure or piled material. Article 10: the construction of new port should give priority to the use of a fire resistance rating, L2, L3-resistant grade control, strict restrictions on the four levels of fire resistance rating. On the original fire resistance rating of low, inadequate fire separation does not comply with the building design fire protection standard (hereinafter buildings》) requirements of the building, structure (included in relics protection except), should be transformed buildings》. Article 11 from abroad a large mechanical facilities of the port, shall conform to or no lower than my fire specification requirements. Specification does not require that you can reference the relevant technical specification in foreign countries, subject to the relevant provisions of the specification of the Chinese translation and design drawings sent port firefighting supervisory authority audit. Chapter 3, article 12 of the fire station, river ports along the coast, the Ministry of the port the fire House layout and building standards law and the Ministry of public security of the fire station building design standards, the establishment of water, land fire station and ancillary facilities. Article 13 of the port the fire station and land (coastline), should be incorporated into the overall planning of ports. The site has been designated a fire station and land (coastline), any unit shall not occupy. Article 14 should be built in fire station port accessible location. Its layout shall be to receive alarm land station 5 minutes and waters within 20 minutes the fire boat reached the edge of the area of responsibility as a general principle. Article 15 the frontiers of fire Pier base outside the waters and the fire shall not be berthed side of other ships and set any obstacle, should ensure that a fire emergency fire-fighting vessels deployed radius of gyration. 16 basic seismic intensity six degrees (included), its fire station building basic seismic intensity should be increased once. Chapter IV article 17 fire water supply shall be share the construction of the port or dedicated fire water supply facilities, and a reliable power supply system and water facilities. Terminal edge fire hydrant should be international shore interface. Article 18 of the fire water supply should make full use of river, Lake, sea, and other natural sources of water. Article 19 of the fire water pipe diameter and fire hydrant settings should be consistent with the requirements of buildings》. Article 20 the fire water pipe corrosion, stale or lack of water, water pressure, water authorities should be replaced, repaired in a timely manner to meet the needs of the fire-fighting water supply. Article 21 the port the fire hydrant specifications must be unified. Remove or move the port the fire hydrants must be approved by the supervisory bodies. Fire hydrant damaged, the port authorities shall promptly repair. Chapter 5: fire truck Road 22 of the planning and construction of the port should be reasonable, a fire road its width, spacing, and turning radius and so should be consistent with buildings》 requirements. Article 23 to any unit or individual may freely mining or occupied area fire road. Temporary mining or occupied, you must be reported to the port agreed in firefighting supervisory bodies. Chapter 6, fire alarm and fire communication 24 port fire fighting supervisory body should establish communication and command system, and with the city fire dispatching Center networking, provides the receiving vessel fire VHF wireless communication devices. Article 25 of the port of focus fire unit, parts should be set and port the fire monitoring bodies Unicom's wired or wireless communication fire alarm equipment. 26 berthing, handling 1000 tons (included) flammable liquefied gas, 5000 tons (included), category b flammable liquid ship quay and total reserves in 10 million tons of oil storage area, depending on the circumstances, the gradual introduction of CCTV or fire alarm installations. Chapter 7: construction and maintenance funds article 27, the port the fire facility construction, belonging to the capital area should be included in the port of the capital investment plan; belong to update, renovation projects, from the update, modification project costs or equipment repair costs in the investment construction. No unit or individual may arbitrarily cut, misappropriation or embezzlement of fire construction investment. Article 28 of the internal construction of port and other causes corrupt or removedRelocation of fire facilities, its reconstruction, repair costs all damaged or demolition units. Chapter i. General provisions of article 29 of this regulation by the Ministry responsible for interpretation. Article 30 of this regulation with effect from 1 May 1992.

No comments:

Post a Comment