1. design process on the lighting control system configuration design generally in lighting design and lighting electrical part of the design and after, according to the requirements of the owners and the lighting design electrical schematics for system configuration. 2. Design the basic steps and the first step in checking method of lighting circuit of lighting and light in nature. 1) each lighting circuit on the light source should be the same type of light source, do not use different types of light sources such as incandescent lamps, fluorescent lamps, inflatable light mixed in a loop. 2) distinguish between lighting circuit is of such a nature as to source or normal power supply. 3) each lighting circuit of maximum load power should be consistent with the dimmer controller or switch controller allows the rated load capacity, should not be running. 4) according to the lighting designer on lighting scenes that lighting circuit partitioning to audit, such as incompatible with the required lighting scenes circuit partitioning. You can make some appropriate circuit adjust lighting circuit partitioning can adapt to the needs of the lighting scene effects, lighting and interior decoration, in the space level, lighting effects and Visual expressiveness of intimate fusion, so that the light combination of a beautiful lighting art environment. The second step in accordance with the prescribed circuit performance, select the appropriate dimmer dimmer selection depends on the nature of the light source, select inappropriate cannot achieve the correct and good lighting effects. As a result of various manufacturers dimmer product on the light source and distribution mode requirements may vary, this part of the contents of configuration recommendations refer to the corresponding product before technical information or directly to the lighting control system manufacturers do detailed technical advice. If a different light source: incandescent lamps (including tungsten, tungsten halogen and quartz lamp), fluorescent lamps, lamps and lighting filled differently, transposes light matching requirements are not the same. The third step requires that you select under lighting controls and other controls in the control panel. Control Panel is to control the dimming system of the main parts, and also the operator directly operate the use interface, select a different function in the control panel should meet the operational requirements of the control, the control system generally have the following control input mode: 1) used to manually control panel at any time to touch on lighting regulation control.
2) uses the time Manager control, automatic control, depending on the time.
3) adopts photoelectric sensing automatic control mode, depending on the ambient light intensity automatic adjustment of the lighting brightness
4) using a handheld remote control.
5) using computer centralized control
6) other control modes and so on. Step 4: select the attachment and integrated control system as required and other related smart systems integration, you can choose the corresponding accessories. The fifth step construction drawing design and equipment configuration inventory preparation 1) design, the construction drawings portions visible intelligent lighting system electrical design related tutorials.
2) system configuration inventory, such as system product type, quantity, use area, notes, and other related information.

No comments:

Post a Comment