Wednesday, December 29, 2010
【 Weak current College 】 Gulf equipment technical characteristics and parameters (9)
(11) other equipment
● GST-HX-M8501/GST-HX-M8502 coding fire alarm sound/light
GST-HX-M8501/GST-HX-M8502 coding fire sound/light alarm is installed in the field of sound or sound and light alarm equipment, fire protection control center fire alarm controller initiated by manually installed in the field of alarm button started directly. After a strong start of acoustic alarms or acousto-optic alarm to remind the purpose of the field note.
GST-HX-M8501/GST-HX-M8502 coding fire alarm sound/light-fast and slow two rhythm siren, fast-paced alarm sound is high or low two sound pressure level optional, can be set by the encoder. Optical display using only super bright red LEDs as the light source, the display striking, long life, low power consumption. You can start the Alerter short external control Terminal, from power-fail signal bus.
And signal bus and power supply bus using polarity 2 convenient bus connections, wiring; with bus power off detection function, to supply bus power, fault information to the controller.
GST-HX-M8501/GST-HX-M8502 coding fire alarm sound/light base using limit design, with anti-removal function, so that the fire alarm sound/light has a unique installation location. Can electronic coding that is simple and convenient.
This device is a patented product, Patent No.: ZL99311721.X.
The main technical indicators are as follows:
◎ Operating voltage: 24V voltage bus: bus, power supply voltage: DC24V
◎ Monitor current: 1mA current ≤ bus, power supply current: 5mA
◎ Current £ GST-HX-M8501: bus current ≤ 5mA, power supply current: 50mA
GST-HX-M8502: bus current ≤ 5mA, supply current ≤ 60mA
◎ Wire: and controller-polarity signal second bus connections, you need two-polarity 24V power supply line
◎ Alarm sound pressure level: loud 85dB, low pressure level over more than 75dB (front 3m level (A weighted))
◎ Using environment: temperature:-10 ℃ ~ + 50¡æ £ ¬2 relative humidity: 95%, no condensation
◎ Dimensions: diameter: 110mm, high: 97.5mm
● BMQ-1 electronic encoder
Conventional detectors encoding you will need to manually set by mechanical dial code to complete the coding efficiency low, technical requirements, and prone to error codes, and in order to facilitate the coding, the bottom of the need to stay out of the detector coding, so easily cause detector on dust, moisture, seal the bad so that probes the overall performance of the variation.
For detectors and other equipment introduce electronic coding, operation simple, easy method (decimal). Use electronic coding, coding is not located at the bottom of the detector, leak-proof quality good, the other by electronic encoder, no need to probe the access controller directly on the detector performance, date of manufacture and checking of historical work data. BMQ-1 type electronic encoder can encode the electronic probes or module address number, year number, batch number, sensitivity, type number of read and write, you can display graphical fire ZF-GST8903 disk addresses, lights and the total number of each lamp corresponding quadratic codes to write and read out, the scene debugging maintenance is very convenient.
The main technical indicators are as follows:
¡Ò: Gulf company may carry out all kinds of electronic encoding detector, modules and display graphical fire ZF-GST8903 disc
◎ Working voltage: DC9V
◎ Working current ≤ 8mA
◎ Standby current: 50A
◎ Using environment: temperature:-10 ℃ ~ + 50 ° c relative humidity ≤ 95%, no condensation
◎ Dimensions: 164mm×64mm×24mm
● GST-5000 color CRT display system
GST-5000 color CRT display system is the Gulf security technology co., Ltd design by the latest generation of fire control centre fire monitoring and management system for fire alarm and fire fighting equipment management and control. Can my company produces GST200, GST500, GST5000 series fire alarm controller (joint-)-featured graphical fire Center monitoring system. Its main functions are: to build graphs monitoring Center; provides multimedia features and equipment fire, fault, action at the voice prompt; graphical display can be partial zoom, and a good guarantee that the image quality is not distorted; can be multiple controller network monitoring, the establishment of monitoring and control system for distributed network graphics.
(1) the system uses a distributed architecture that can be used in stand-alone, LAN, Internet operation. You can also manage multiple different types of controllers, multiple controller network monitor, the user can view the Internet or local area network, monitor system performance.
(2) can be done on this system and all devices control actions (start, stop, quarantine, release device, etc), provides fire alarm controller (linkage) of the same control modes, and can operate on the controller and the settings.
(3) the user can at any time through the communications test functionality test system data communication status, ensuring reliable operation of the system.
(4) when the fire broke out in the on-site equipment, the actions, failure, quarantine, in the appropriate location for the graphics flashing graphics, along with the text display, voice prompts, and so on, automatically eject the editing of the corresponding device supporting programmes in emergency situations to tips on duty to complete the necessary contingency operations. These features are very useful command field fire.
(5) simple, intuitive and complete graphical user interface, you can monitor and automatically or manually see floor equipment distribution graph.
(6) easy, intuitive and quick buttons, you can improve work efficiency, handling the exception information in a timely manner.
(7) available through theAnd remote real time print device exception information; browse system controller information, floor information, history of linking formulas, users, support for multiple conditions combined query various fire, failure, and other historical records.
(8) system provides multi-level password for system security management to prevent accidental operation.
(9) the complete database management functions, and data backup function, you can send your data loss to a minimum, ensure that your system security.
(10) provided automatic upgrading client and file download tool, able to timely update the required system files.
Labels:
[:]