【 Weak current College 】 public entertainment fire identity standards




First to standardize personnel public entertainment fire identity settings, cultivate social unit of fire safety self management skills, raise the level of fire management, under the provincial implementation units fire safety standardization management implementation views, develop this standard.

The second article this standard applies to the following public entertainment:

(A) theater, performance, such as ring, Auditorium, show venues;

(B) of the song and dance halls, karaoke and dance entertainment, Office, etc.;

(3) have the entertainment function of nightclubs, music Cafe and catering establishments;

(Iv) entertainment, video games room, Internet Cafe, fun, amusement;

(5) the bowling alley, rink, billiard Hall, gym, sauna, chess room and other business fitness and leisure establishments.

Article 3, public entertainment main entrances and striking position should set the overall layout logo to indicate units of fire and water (natural water sources, fire hydrant and the municipal fire hydrant), pump adapter, fire engines, fire safety focus areas, safety and evacuation routes, major fire facilities location, etc. The total layout ID should not be less than 0.5 square meters.

4 multi-tiered public entertainment business premises should be on each floor layout identifies, with an emphasis on marked this layer evacuation route, safe export, indoor fire facilities location, etc.

5 public entertainment main entrances, major evacuation channels should make use of the electronic screen, fixed publicity layout, set the publicity law regulations and fire protection law provincial people's Government, the provincial provisions on fire safety and fire safety management of the company's commitment to identity, and set the propaganda unit safety philosophy of slogans and public fire safety matters, fire alarm, security, evacuation, self-help knowledge and so escape.

Article 6 of the place of public entertainment bar, workplaces, fire control rooms, offices, distribution, and other parts of the system should be set to fire safety, fire safety duties and other duties.

7 public entertainment should be striking position settings "prohibition of the use of open fire" logo.

8 public entertainment rooms in the upper part of the door should be set after a fire evacuation instructions.

9 public entertainment fire facilities should use the luminous identity.

Article 10 public entertainment in fire extinguishers, fire extinguisher should be placed in the box, drop point, fire extinguishers, fire extinguisher box lid above should be set to identify the name, operation, use, maintenance, repair and maintenance time.

Article 11 on indoor hydrant box should be set to indicate the name, identified operational use methods, responsible for maintenance and repair time, prompt may not occupy, occlusion.

Article 12 manual fire alarm button nearby should set fire alarm button identifies and indicates the method to use.

13 building automatic fire-fighting facilities must be made to set the automatic fire-fighting facilities building inspection identified, marked with the system name, use number, maintenance, inspection, inspection, inspection dates, and other content.

Building automatic fire-fighting facilities qualified ID should be the following requirements: have room for fire control, posted at alarm control cabinet; only the upper-left corner of the sprinkler system, posted at pump control cabinet of the upper-left corner; other times, posted in a prominent and attended.

Article 14 public entertainment is equipped with fire control room or fire control equipment, its identity setting is also in the light of the fire control room fire identity management standards.

Article 15 of the safety of the public entertainment exports and evacuation door just above should set lights "security export" flag

Article 16 shall be the aisle evacuation lighting evacuation signage, set the location should be in the evacuation of the aisle and the height from the floor, corner of 1 m of wall, and spacing should not be greater than 20 m; for a bag-shaped walkways, should not be greater than 10 m; in the aisle of corner area, should not be greater than 1 m.

17 public entertainment should evacuate the aisle and primary evacuation route from the ground an additional can maintain Visual continuous lights evacuation signage or phosphorescent evacuation signs.

Article 18 on the door safety outlet should be set to "no locking" identification; changbishi fire door should be set to "fire door please shut off" logo; normal elevator should be near the elevator door and set the "do not use the elevator when the fire escape" logo.

Article 19 has a fire-alarm escape door lock security lighting should be set in the upper part of the export security export ID, escape doors above the striking position should be marked using the methods and considerations.

Article 20 underground fire hydrants, water pump outdoors combined with a nearby wall should set identity that indicate the name, usage, maintenance, repair and maintenance time.

Article 21 of the fire water tank striking position should set identity, marked with the intake, volume.

Article 22 shall be set up near the fire road fire road marking, marked with the words "fire truck road" and the width of the tip is strictly prohibited.

Article 23 fire safety campaign to identify content should fire safety management work is regularly updated.

24 units should strengthen the fire identified maintenance, administration, if it is damaged, missing and should be replaced in a timely manner.

25 fire facilities equipment identifies needs identified maintenance responsibility, check the maintenance time, maintaining responsible change and each inspection, maintenance, should be specified.

26 national standards and the standards on the fire identify specifications, dimensions, should be required to produce; not provided for by the provincial and municipal fire departments according to local conditions and be clear.