【 Weak current College 】 of supermarket fire key---Power By 【 China power house network 】



Should seize the source, do the basic work, in the following areas to:
(A) to ensure that personnel access and evacuation channel area. Supermarket business Hall as public places, customers need the required area should be fully taken into account. This area at present, there is no normative explicitly, but according to the actual situation and reference the foreign experience, shelves with people occupy public area ratio: integrated large supermarkets or multilayer supermarkets generally not less than 1/1.5; smaller supermarkets at not less than 1/1. The public area of the passenger traffic, average by customer during the peak time traffic capita area of not less than 0.4 square meters. Counter group layout, set the distance between the Group and not less than three metres.
(B) of the supermarket of the architectural design fire protection standard and the high civil building design fire protection standard law Division fire partitions. Multilayer supermarket land press 2500 square meters for a partition, the underground press 500 square meters to a fire partitions; such as supermarket fitted with sprinkler systems, fire protection district area doubled; senior market if equipped with automatic fire alarm systems and automatic sprinkler system, and does not burn or nonflammable materials decoration, floor supermarket fire compartment area extends to 4000 square meters, the underground fire compartment area supermarkets can be extended to 2000 square meters.
(3) supermarket small transit warehouse, service processing and household appliances, watches, eyewear repair shop, and so should be set with the business office is separate, strictly control the use of the open fire.
(4) oil-immersed power transformer should not be located in the basement supermarket, if you have set, you should avoid the personnel-intensive areas and entrances, and the application of the fire resistance is not lower than the partition and 3H fire resistance is not lower than the floor and the other 2H parts separated by a door in the wall, should be used in class a fire door, transformer following should have all the storage of the transformer oil storage facilities of the accident.
(5) air-conditioner room into the level of fire protection District Branch, should set fire to the fire safety valve automatically closes. Air duct on the use of insulation, sound-absorbing materials should use inflammable or nonflammable materials.
1. strengthen the daily fire management
Supermarkets under the FPPA and the Ministry of public security requirements of Decree No. 61, conscientiously implement fire safety management responsibilities. Clear the supermarket of the legal representative of this unit is responsible for fire safety full, Executive heads should be responsible for the supermarket fire safety management work, is also a supermarket in charge of fire safety. Supermarket should establish and improve fire safety management system, fire safety practices and earnest; supermarket building recursively fire safety responsibility system, fire safety responsibility agreement signed; on the rental counter, its fire safety responsibilities must distinguish between, and the integration of unified management of supermarkets; supermarket should be equipped with the necessary and part-time fire safety management personnel, focus on workers and on a regular basis trades personnel for fire safety education and training, and often organized fire safety inspections and timely elimination of fire danger; to establish and strengthen the obligation to draw up the fire, and fire-fighting, evacuation plans and regularly organize walkthrough; automatic fire-fighting facilities at the supermarket to establish a regular inspection testing and maintenance of the system, and enhance fire control operations personnel training and on-duty checks; to periodically check the maintenance of fire-fighting equipment, fire apparatus can be used; to establish a good fire archives, on the work of supermarket fire safety seriously. 2. in rigorous fire management
Supermarket in the Setup installation, renovation and repair, counter, the business district and the decoration areas should be separated by a fire, using electric welding and cutting operations, should be fulfilled before the job fire with fire and approval system, the site must have someone monitoring, fire equipment, fire fighting.
III. strengthening the flammable materials management
Nail Polish in operating the supermarket, mousse, typing paper, butane gas, and other inflammable dangerous commodities, should control within the two days of sales, at the same time to prevent the sunlight and other high temperature electric heating apparatus for separating, properly. Underground supermarket sales of fireworks are strictly forbidden, the starting gun paper, gasoline, kerosene, alcohol, paint, flammable goods. Clock, camera repair job using alcohol, gasoline and other inflammable liquids cleaning parts, on-site prohibit the open fire. A small amount of daily use, to flammable liquid into a closed container, ad, and is not used to its dedicated on-site warehouse, shall not be stored.
4. set the striking evacuation route signage, security exit indicators lights, "" no smoking "signs at the same time, to ensure the safe evacuation in the supermarket logo clearly effective, simple and straightforward, the evacuation route-smoking sign stand out. Wet spray eqnipment is automatic sprinkler system detects system features a simple and practical testing device. In the wet, preaction systems are called partition network terminal or system network terminal settings. Eqnipment General connection pipe, pressure gauge, control valves and pipes, conditional or remote pressure and flow measurement device and solenoid valve. General requirements for installation is simple, reliable measurement results.
1. fire water tank; 2. inlet elbow 1.2m×1.2m square anti Vortex Board, pool bottom distance suction pipe diameter 1.5 times, but a minimum 152mm; 3. suction pipe; 4. Frost cover; 5. eliminate the stress of flexible connection pipe; 6. gate valve; 7. eccentric reducer joints; 8. suction pressure gauge; 9. horizontal pump body can open fire pump; 10-automatic exhaust; 11-outlet pressure gauge; 12. reductive of outlet tee; 13. outlet check valve; 14. pressure valve; 15. outlet; 16. spherical valves or dripping water; 17. hose valve hose valves collection tube; 18. pipe support; 19. indicative gate or indicative butterfly valve.
Alarm set location, close to the alarm valve, make it easy to hear the ring tone. Distance alarm 3m, hydraulic pressure at the alarm injector .05mpa, its alarm intensity should be not less than 70dB.
On dry alarm valve group installation site requirements. Dry alarm valve group is dry sprinkler fire extinguishing system, the main component, dry extinguishing system applicable ambient temperature is below 4 ° c and above 70 ° c, low temperature, the system uses the site likely frozen, dry alarm valve groupShould be installed in a place without freezing. Mainly because of the dry alarm valve group is servo, water side of the pipeline is filled with water, dry valve system side-air Chamber, in order to ensure their tightness generally filled with the design requirements of seal water. If dry valve installation place frozen, dry valve water frozen parts may occur, especially in dry valve Chamber side of seal water more prone to freezing, the influence of light by opening of the valve, serious it may make dry valve is compromised.