Tuesday, December 21, 2010

【 Weak current College 】 fire safety Standardization Management main content


1. fire safety standardization management software-building

(A) implement incrementally, and post the fire safety duties. Guidance unit to develop the following nine categories of duties:

1. units of fire safety responsibilities

2, fire safety responsible duties

3. fire safety Manager duties

4, fire work duties centralized management functions

5, fire control room attendant duties

6, fire-fighting facilities operation and maintenance personnel responsibilities

7, the sales staff responsibilities

8, security officers responsibilities

9. electric welders, electricians operations staff responsibilities

(Ii) improve the fire safety management system. Guide units sound 12 class system:

1. fire safety education and training system

2, fire safety inspections and inspection system

3, safe evacuation facilities management system

4, fire control room shift system

5. fire-fighting equipment maintenance management system

6. fire hazard modification system

7, the use of fire electricity safety management system

8, Allied and obligations of the organization management system for the fire brigade

9, fire fighting and emergency evacuation plan for training system (two Echelon construction)

10, the use of fire electricity gas equipment procurement system

11, gas and electrical equipment check management system

12, fire safety work evaluation rewards

(3) uniform fire archives books. Guidance unit consolidated the following five types of archives, books, and printed as a book:

1. fire safety archives (including units of the basic conditions and internal management of the two most and stapled to form a hard surface flyer)

2, fire safety inspection records (in accordance with the requirements of the Ministry of public security Decree 61 10 types of content)

3, fire inspection records (in accordance with the requirements of the Ministry of public security Decree 61 6 classes)

4, fire control room shift records [including fire facilities, fire alarm controller of daily operation (self-test printing paste in fire control room shift inspection records), fire, three parts of the disposition, one page for each day of the month this]

5. other necessary fire safety work records.

(4) establish procedures for fire safety. Guidance unit to develop the following nine categories of practice:

1, fire control room watchkeeping officer fire disposal program

2. employees see fire fire disposal procedures when

3, automatic fire fighting system procedures

4, fire radio operating procedures

5. transformer substation room practice

6, electrical and gas line installation practice

7, hot work procedures

8. fire accident rehabilitation program

9. other necessary fire safety practice

(5) suspension, post related construction standards. Guide units will fire safety duties, systems and operating procedures for the consolidated printed and bound, and released to each team, each employee hands, hands a book, and some of the key content is posted, hanging.

1. fire safety organizations to staff photos made in the form of framework plans to fire work centralized management departments of the Office.

2, fire safety and fire prevention management centralized management functions of the job duties of the Office of the respective hoisted.

3, fire control room hanging on-duty system, a fire watch duties and disposal procedures.

4. the fire pump room, smoke House, distribution, and other fire safety important parts suspension related staff responsibilities and procedures.

2. fire safety standardization management hardware building

(A) improve the fire-fighting facilities maintenance management standards. Guidance unit developed six types of standards, and printed and bound:

1. evacuation facilities maintenance management standards

2. fire shutter system and fire door maintenance management standards

3, indoor hydrant system maintenance management standards

4. automatic fire alarm system maintenance management standards

5, automatic sprinkler systems maintenance management standards

6, smoke exhaust system maintenance management standards

Unified daily fire fighting facilities maintenance and management of the individual checks and inspections, examine the record linkage table's style and content, and integrate them into the fire inspections, fire safety inspection records for flats, learning, knowledge and experience.

(B) specification of fire safety identification. Guide units in accordance with the following requirements for fire safety ID:

1, fire doors, fire shutter, exits, security facilities of export, the evacuation of nearby distance set yellow alert level.

2. in each floor of the obvious location set evacuation instructions diagram indicating the figure that the evacuation route, security, personnel location and the necessary text description.

3, in the evacuation staircases or with access control systems, and other significant locations set "safe export" identity and usage tips.

4. smoke fire pump, blower, pump adapter, regulators pumps, pressure tank, fire shutter controller and other important fire facilities Department settings management responsibility sign, name and indicate the fire facility management responsibility of the person's name.

5, in fire control cabinet, wet alarm valve, eqnipment, test water valve and other pipeline control valves and set identity, indicate the buttons, valve control area, regional andNormal off condition.

6, in evacuation channels, safe, fire hydrant, fire protection, plumbing, fire extinguishers and other fire safety focus areas and fire-fighting facilities Department settings check sheet and using diagrams, explicitly check the content, frequency, and the person responsible for completing the management responsibility.

No comments: