Wednesday, December 15, 2010

【 Weak current College 】 warehouse fire---textile raw materials warehouse fire-Power By 【 China power house network 】


Textile raw materials warehouse is used for the stacking of plant fiber. Animal fiber and chemical fiber, textile raw materials. Storage of textile raw materials warehouse and Depot fire often lead to catastrophe, therefore, to do this kind of warehouse fire prevention is extremely important. First, fire risk 1. textile raw materials cause spontaneous and smoldering fires. 2. Reservoir area layout is not reasonable or not in compliance with the fire and asked, production, domestic fire accidentally, Mars landed reservoir, ignite materials causing a fire. 3. manage loose, Manager or unrelated persons smoking or use of the open fire, leaving the fire hazard. 4. electrical lines of improper installation, repair, spark caused a short circuit or lighting baked fuel fire. 5. raw material library. Open library for Lightning and fire. 2. fire prevention measures 1, warehouses should avoid the bustling downtown area, close to the urban edge and have the water source the place, in the area of perennial dominant wind direction on the wind or the side, and to build fences or take other protection measures. Raw materials warehousing warehouse, yard and outdoor substations, building defenses spacing should be according to the relevant State regulations for specific requirements. 2. raw material warehouse and heaps of combustible building venue shall be built, it is set within the Treasury, Office of the Clerk's lounge. Treasury of refractory grade, layers and the area shall be consistent with the relevant provisions. 3. Treasury stocks of raw materials should have certain limits. Stacking between channels, the width of the main channel at least 2 metres, a small channel at least keep 1.5 metres to facilitate operations and ventilation. In primary and secondary fire rating coffers, stack high pitch roof not less than 2 m; in the gable roof and three flame resistant grade coffers, stack high margin room beam is not less than 1 m. 4, large, semi open yard total reserves of more than 5000 tons of raw materials, should be located in yard, yard fire separation between at least 30 meters. At the end of each stack size should be less than 100 square meters, the stack height is less than 6 metres. Stacking block layout, each group of less than 6 stack, stack and stack the distance between greater than 6 m, group and the distance between groups larger than 15 metres. Stacking and exterior wall distance greater than 5 metres. Stack base needed moisture-proof, heap top cover with cloth cover to prevent rain, fire fall into the stack. Do not use iron and other metal binding cover cloth to prevent lightning misunderstanded. 5. Treasury shall power lines and electrical installations, the library can be used in light lighting. Power supply battery has not been changed, the library uses electricity socket should be in the library, with no external damage without joints of rubber sheath cable into the library, after the cut off the power immediately. Cords, outlets, gates shall not be below the dumps raw materials. 6. the area of wire should be buried cables. Use overhead lines, from the outside through the Treasury, line do not pile of raw materials. Area for the transport of raw materials over the channel, and overhead lines must be from 5 meters above the sea level. 7. electrical circuits and equipment must not overload operation. Weekly on the line and device to check more than once a year for two more insulated shake. If you find the short circuit, aging, and other anomalies, immediately stop using, make troubleshooting. 8. steam locomotives, diesel locomotives, cars, tractors, etc. into the reservoir, a fireproof hood. Steam locomotive shall platform in Qing dynasty. Stay, automobile exhaust pipe should stay away from combustibles, stop immediately flame. 9 £ ® for strapping raw cotton. Chemical fibre metal, iron wire not fieriness or beating, don't drag on the ground to prevent Mars. 10. open fires is forbidden in the library and smoking. If required in the area of 30 m to open flame should report it to the job, the leaders agreed to and specialist care, after the end of the job should be thoroughly cleaned from fire. 11. the raw material warehouse lightning equipment should be set up, open yard need independent lightning, lightning stroke prevention. 12. keep the area clean, prevent the Treasury ground scrap, the lower corner, and other fuel combustion. The package has been damaged by the raw material should be wrapped up after the release of the crib, or powder packs on a separate storage. 13. raw materials are checked on a regular basis, and turn the buttress ventilation. 14. Every 200 square meters of raw materials library, each 150 square meters of outdoor stacking, desired configuration fire extinguisher 2, fire water 0.5 tons, small bucket 4, as well as hook, spade, and other firefighting equipment. 15, found to be wet or soiled grease stains of cotton, linen and its products, unpacking after drying, soaks into the library stack.

No comments:

Post a Comment