【 Weak current College 】 fire control room fire identity management standards



First to standardize the fire control room fire identity and security management, automatic fire-fighting facilities, improving the level of fire management, under the provincial implementation units fire safety standardization management implementation views, develop this standard.

The second article of this standard is applicable to automatic fire fighting system of units, fire control room or fire control parts.

Third fire control room door should set identity, marked "fire control room on fire"-free.

Article 4 indoor fire control should set the fire control room management system "," fire control room watchkeeping personnel responsibility "," fire disposal program, the automatic fire alarm system maintenance management practices such as the system identity, and suspension or posted at the wall of the control room.

5 fire control rooms should have show protected buildings of the important parts, exits, fire protection equipment is located in the plane or simulation.

(A) the equipment has a fire-fighting capabilities, must display the smoke and heat detector, the alarm button, fire hydrant, fire-fighting facilities, and in the control room walls prominently set fire and evacuation route maps that indicate the fire hydrant, fire escape and evacuation routes, etc.

(Ii) equipment without fire-fighting capabilities, should be in the control room walls prominently set fire facilities and evacuation route maps that indicate the various fire facilities, secure export location and evacuation routes.

(3) different architectural floor structure, should set the standard in the walls of fire-fighting and evacuation plans, other floor fire facilities and evacuation plans should be in the fire control rooms establish archives of post secondary volume.

6 automatic fire-fighting facilities inspection after posting the building automatic fire-fighting facilities inspection certificate of identity, marked with the system name, use number, maintenance, inspection, inspection, inspection dates, and other content.

Building automatic fire-fighting facilities qualified ID should be the following requirements: have a fire control cabinet works posted at linkage control cabinet; only the upper-left corner of the automatic fire alarm system engineering, posted at alarm control cabinet; only the upper-left corner of the sprinkler system engineering, posted at the pump to the upper-left corner of the control cabinet.

7 fire control rooms should be equipped with not less than 2 with 4 kg ABC powder fire extinguishers, fire extinguishers, fire extinguishers to place point box lid above should be set to identify the name, operation, use, maintenance, repair and maintenance time.

8 fire control room operator should receive post function or the provincial fire agencies, the training of qualified certificates; the operator should keep in mind control room duties, familiar with fire disposal procedures, automatic fire-fighting procedures.

9 fire control rooms should implement on-duty system, 24-hour nonbreaking.

Article 10 the daily fire control rooms should fill out the on-duty records and fire facilities inspections, inspection, maintenance records, duty, inspection, maintenance staff signature archive for future reference.

Article 11 should fire control room will return the following data consolidation, storage in a volume control room:

(A) fire control room related functions, System;

(Ii) fire-fighting facilities and evacuation of the roadmap;

(3) fire-fighting facilities maintenance agreements;

(4) automatic fire-fighting facilities annual inspection report, quarter, month check test conditions;

(5) fire control room operator training for seafarers.

Article 12 of the fire safety campaign identifies content should fire safety management work is regularly updated.

13 units should strengthen the fire identified maintenance, administration, if it is damaged, missing and should be replaced in a timely manner.

Article 14 of the fire-fighting equipment identifies the need to identify those responsible for the maintenance, checking the maintenance time, maintaining responsible change and each inspection, maintenance, should be specified.

Article 15, the national standards and the standards on the fire identify specifications, dimensions, should be required to produce; not provided for by the provincial and municipal fire departments according to local conditions and be clear.