Monday, February 7, 2011
【 Weak current College 】 Fireworks enterprise security checks---Power By 【 China power house network 】
Fireworks seasonal operation has an obvious, especially during the Spring Festival is the centralized sales period. Fireworks display from the "no" instead of "limited," the chances of an accident increased significantly. Therefore, in addition to the normal security check that centralized sales period, should strengthen the fireworks in the business of law enforcement and inspection. Fireworks enterprises a comprehensive check content, business unit qualification Fireworks business units (including storage, wholesale, retail, interim operating outlets) and in accordance with law and commercial registration, Fireworks sales license. Business unit shall permit prescribed time and location within the sales. Second, security, organization and staffing 1. Fireworks wholesale unit must set the safety management of institutions to a full-time production safety management staffing up in this Enterprise 1 per cent of the total, and at least 1 full-time security production management personnel. 2. Fireworks retail units and temporary part-time sales outlets should be equipped with security managers. 3.1000 m2 more Fireworks warehouses supervisory personnel, Allied security shall not be less than 5, 1000 m2 of fireworks warehouses supervisory personnel, Allied security shall not be less than 2 people. 3. all types of personnel qualification Fireworks business units of all types of personnel must be specially trained in the safe production, and obtained the qualification certificate. 1. operating units of the main responsible, safe production managers, professional security officer, in charge of the warehouse with Fireworks and sales activities of security knowledge and regulatory capacity, and safety production supervision and regulation Department has safety examination certificate. 2. the driver, escort members must be legally obtained qualification certificates, certificates. 3. practitioners must conduct safety education and technical training, gain employment job cards. IV. safety in production responsibility system of fireworks management units should be strictly to develop various types of personnel safety in production responsibility system. Responsibility system generally include the following personnel accountability: Fireworks wholesale directors safety in production responsibility system; safety management personnel safety in production responsibility system; fireworks storage warehouse workplace safety in production responsibility system; custody personnel safety in production responsibility system; security personnel safety in production responsibility system; handling personnel safety in production responsibility system; special operations personnel safety in production responsibility system; drivers, escort staff safety in production responsibility system. 5. safety rules and safety goals management systems; safety equipment and facilities management systems; safety education and training and assessment management system; duty management system; PPE equipment, usage management system; fire-fighting facilities, equipment management system; when hot job management system; security checks and accident modification management system; major hazard assessment and control management system; production safety accident reporting and handling management systems; special job management system; procurement management system; safety measures for the management system; safety production and management systems; external personnel management system; access, stay, parking management system. 6. practice monitoring equipment operating rules; custody and sales practices; quality inspection practices; temperature measuring, measuring humidity operating rules; handling, loading and operation procedures. Fireworks business unit hardware check content inspection project checks the contents of the safety distance of the city of five outside the loop, 300m range can only set a Fireworks retail locations; and five loops within the region, you can only set within 500m a Fireworks retail space gas stations, oil and other flammable and explosive hazardous materials production, management, storage facilities, schools, kindergartens, gymnasium (field), hospitals, and other personnel within the Assembly places 100m fitted Fireworks sales places more than 1000 m2 warehouse and town planning at the edge of the safety distance of ≥ 130m and residential areas, schools, kindergartens, industrial area, gas station, dangerous goods production enterprises, an army post, hospitals, tourist areas, and other densely populated areas of the safety distance of ≥ 80m and railway, two or more roads, 35kv such high voltage transmission lines of the safety distance of ≥ 40m1000 m2 following storage warehouse and town planning at the edge of the safety distance of ≥ 110m and residential areas, schools, kindergartens, industrial area, gas station, dangerous goods production enterprises, an army post, hospitals, tourist areas, and other densely populated areas of the safety distance of ≥ 65m and railway, two or more roads, 35kv such high voltage transmission lines of the safety distance of ≥ 35m protective equipment must be employed with anti-static overalls, anti-static work hat, anti-static shoes and protective gloves. Security ID hanging license and unified identity management places security identity is strictly forbidden smoking ban firework Fireworks vehicle loading and unloading must be flame warehouse security identity warehouse security identity inthe no pyrotechnics inthe smoking ban Fireworks libraries within the prohibited fire into galleries close mobile motor vehicles into the library must be installed in non-flame Cap car loading and unloading of vehicles and repair must be flame prohibit sales of variety shell, La guns, artillery, only to fall and brand impact of paper product safety operations handling operations, only a single pallet, collision, drag, tumbling, inverted and violent vibration, forbids the use of iron tools storage volume retail places a temporary holding products must not exceed 50 boxes per carton weight not exceeding 35 kg, shall not street sales. have relatively independent retail establishments, counters, special sales, selling and storage of m21000 area of not less than 20 m2 above storage centre and town planning at the edge of the safety distance of ≥ 130m and residential areas, schools, kindergartens, industrial area, gas station, dangerous goods production enterprises, an army post, hospitals, tourist areas, and other densely populated areas of the safety distance of ≥ 80m and railway, two or more roads, 35kv such high voltage transmission lines of the safety distance of ≥ 40m1000 m2 following storage warehouse and town planning at the edge of the safety distance of ≥ 110m and residential areas, schools, kindergartens, industrial area, gas station, dangerous goods production enterprises, an army post, hospitals, tourist areas, and other densely populated areas of the safety distance of ≥ 65m and railway, two or more roads, 35kv such high voltage transmission lines of the safety distance of ≥ 35m products stacking Fireworks must be boxed stack stack, the distance between the pile should be not less than 0.70m, distance from the Interior of stackingShould not be less than the height of stacking 0.45m, should not exceed 2.5m, shelf than 1.85m, handling channel width should be not less than 2.0m Treasury of doors, Windows and doors of the ground to the Treasury should be a two-tier, shall open outwards; shall not set the threshold, door width not less than the inner door to the ventilation 1.2m with door, door of the following to prevent small animals measures form the Treasury should be able to open all Windows should configure bars and metal net Treasury ground should lay flooring or set 30% m high stack frame. Wood flooring, wooden pallet racks and use of nails, nail head should be below the outer surface of the wooden 3-m above, nail hole to fill with PuTTY is fire-and explosion-proof requirements of the Treasury should have temperature measuring, measuring humidity meter, and a daily check and register. The entrance of the warehouse, should be set to eliminate body electrostatic devices, grounding resistance must not be greater than 10 Ohm Treasury lighting should be used in explosion-proof, and libraries within the switch also need explosion fireworks storage area shall be set, tea boiler, furnace, cooking facilities open fires for heating, not located accommodation living room Fireworks retail units must be made in accordance with the national technical specifications relating to fire, configure two or more 5 kg of water system, fire extinguisher, equipped with emergency rescue equipment
Labels:
[:]
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment