Tuesday, February 14, 2012

【 Weak current College 】 Gulf equipment technical characteristics and parameters (1)---Power By 【 China power house network 】



Table of contents
(A) fire alarm controller 1
● JB-QT-GST5000 type control center fire auto-alarm host 1
● JB-QG-GST5000 type Control Center 3 automatic fire alarm host
● JB-QB-GST500-type fire alarm controller (linkage) 5
● JB-QB-GST200-type fire alarm controller (linkage) 7
(Ii) fire detector 9
● JTY-GD-G3 type intelligent photoelectric smoke detector 9
● JTW-ZCD-G3N type intelligent electronic differential fixed temperature heat detector 11
● JTY-GF-GST104-non-coding photoelectric smoke detector 12
● JTWB-ZCD-G1 (A) non-encoded electronic differential fixed temperature heat detector 12
● BT-KVA001 coding combustible roof household 13
● BT-KVA002 coding combustible wall-mounted home 14
● JTY-HS-G2-smart style infrared beam smoke detector 15
● JTW-LDB-100 type intelligent cable type heat detector 16
● JTG-ZW-G1-smart 17 UV flame detector
● JTF-GOM-GST601 type intelligent gas temperature composite detector 18
● JTGB-ZM-GST501/I/I-type explosion-proof 19 UV flame detector
(3) alarm buttons 20
● J-SAP-8401-manual fire alarm buttons 20
● J-SAP-8402-manual fire alarm button (with the phone jack) 21
● LD-8403-intelligent code 22 fire hydrant alarm button
● LD-8404 type intelligent encoding fire hydrant alarm button 23
(4) onsite module and interface device 24
● LD-8300-monitoring module 24
● LD-8301-Smart encoding for single-input/single-output module 25
● LD-8303 intelligent encoding two-input/output modules-26
● LD-8304 coding fire phone module 27
● LD-8305 coding fire radio switch module 27
● LD-8311-bus 28 relay fiber interface
● LD-8313-bus isolator 29
● LD-8319 coding repeaters 30
● LD-8320 active Terminal 31
(5) fire displays disc 32
● ZF-101 fire displays disc 32
● ZF-500 type Chinese character LCD display disk 33 fire
● ZF-GST8903-graphical fire show tray 34
(6) power 35
● GST-DY-100-type power supply box 35
● GST-DY-200 type intelligent power supply unit 36
● GST-LD-D02-intelligent power plate 37
(VII) fire broadcasting system 38
• Bus system fire emergency broadcasting system 38
«More wire fire emergency broadcasting system is 39
(8) fire telephone system 40
• Bus system fire telephone system 40
«More wire fire telephone system 41
(9) 42 gas fire control
● LD-QKP06 type gas fire extinguishing control plate 42
● Gas extinguishing control card 43
● LD-8317A-gas spray led 44
● LD-8318A-emergency stop-button start/45
(10) many wire linkage control device 46
● KZK-100-multiple wire control card 46
● LD-KZC-100-multi-line system CPU control card (spare) 47
● LD-8302C type conversion interface module 48
(11) other devices 49
● GST-HX-M8501/GST-HX-M8502 coding fire alarm sound/49
● BMQ-1 electronic encoder 50
● GST-5000 color CRT display system 51

Equipment performance characteristics
GST licensing distribution intelligent fire alarm and fire control system is the Hudson Bay Company successfully developed high-tech fire electronic products, the technology mature, their performance characteristics are as follows:
(A) fire alarm controller
● JB-QT-GST5000 type control center fire auto-alarm host
Design uses JB-QT-GST5000 type Chinese character LCD display fire alarm controller (linkage) as the control center alarm controller, its main characteristics are as follows:
Big-screen liquid crystal display Chinese characters, various alarm status information can be intuitive to Chinese characters are displayed on the screen to make it easy for users to use; you can observe the work of an intelligent dynamic probes for curve for the scene of actual environmental conditions; controller with powerful Panel control and operating functions, a variety of feature comprehensive, simple and convenient.
The controller has a modular design, highly intelligent features, together with the smart probe composition distribution intelligent fire alarm systems, systems of work high reliability and greatly reduces false positives.
System internal parallel bus data transfer, the main control board and the circuit board for information transmission between a query, it would not affect multiple loop machine inspection speed, fast, accurate information transmission.
All bus control system wiring flexibility, you can use alarm point and linkage point total circuit wiring, wiring simple; you can also use alarm point and linkage dotted circuit wiring methods, systems, and high reliability.
The controller has a very strong field programming capability, the loop device interdisciplinary collaborationDynamic and diverse character information note, bus system control devices and much line control devices, such as the linkage between can live programming.
The controller can be completed automation and manual control of the external fire-fighting equipment, which is charged with manual control mode with direct manual control of the output and the encoding key combinations manually control output method, any address within the code point can be occupied by a variety of encoding detector or by the use of various encoding module, design flexibility. Linkage control equipment use 24V DC power supply, making interaction device failure will not affect the normal work of the host.
The main technical indicators are as follows:
◎ LCD size: 320 × 240 graphic dot matrix, you can display Chinese characters 12 rows
◎ Controller capacity:
A. system capacity expanded to 40 block 242 address coding circuit for a maximum capacity of 9680 addresses coding points.
B. external 64 fire show up; interconnection maximum 32-other types of controller.
C. multiple wire control points and direct manual control can bus requires configuration.
◎ Wire:
A. controller and detector using polarity signal second bus connections, and each kind of control modules in addition to the promise of 2 bus out, plus two DC24V power bus.
B. and the other type of controller using polar II bus connection, fire warning shows up, plus two DC24V power bus.
C. color CRT system uses four-core flat telephone line connection through RS-232 standard interfaces, maximum length should not exceed 15m connector.
◎ Using environment: temperature: 0 ° c ~ + 40 ° c relative humidity ≤ 95%, no condensation
¡Ò main power for power: AC 220V; controller by electron DC24V24Ah sealed lead battery; electric as prepared by the linkage DC24V24Ah sealed lead batteries.
◎ Power consumption ≤ 150W
◎ Dimensions: 1080mm×1113mm×1350mm
◎ Bus communication distance 1.5 km
◎ Have RS-232, and RS-485 interface
● JB-QG-GST5000 type control center fire auto-alarm host
Design uses JB-QG-GST5000 type Chinese character LCD display fire alarm controller (linkage) as the control center alarm controller, its main characteristics are as follows:
Big-screen liquid crystal display Chinese characters, various alarm status information can be intuitive to Chinese characters are displayed on the screen to make it easy for users to use; you can observe the work of an intelligent dynamic probes for curve for the scene of actual environmental conditions; controller with powerful Panel control and operating functions, a variety of feature comprehensive, simple and convenient.
The controller has a modular design, highly intelligent features, together with the smart probe composition distribution intelligent fire alarm systems, systems of work high reliability and greatly reduces false positives.
System internal parallel bus data transfer, the main control board and the circuit board for information transmission between a query, it would not affect multiple loop machine inspection speed, fast, accurate information transmission.
All bus control system wiring flexibility, you can use alarm point and linkage point total circuit wiring, wiring simple; you can also use alarm point and linkage dotted circuit wiring methods, systems, and high reliability.
The controller has a very strong field programming capability, the circuit cross-linkage between devices, various Chinese character information note, bus system control devices and much line control devices, such as the linkage between can live programming.
The controller can be completed automation and manual control of the external fire-fighting equipment, which is charged with manual control mode with direct manual control of the output and the encoding key combinations manually control output method, any address within the code point can be occupied by a variety of encoding detector or by the use of various encoding module, design flexibility. Linkage control equipment use 24V DC power supply, making interaction device failure will not affect the normal work of the host.
The main technical indicators are as follows:
◎ LCD size: 320 × 240 graphic dot matrix, you can display Chinese characters 12 rows
◎ Controller capacity:
A. system capacity expanded to 40 block 242 address coding circuit for a maximum capacity of 9680 addresses coding points.
B. external 64 fire show up; interconnection maximum 32-other types of controller.
C. multiple wire control points and direct manual control can bus requires configuration.
◎ Wire:
A. controller and detector using polarity signal second bus connections, and each kind of control modules in addition to the promise of 2 bus out, plus two DC24V power bus.
B. and the other type of controller using polar II bus connection, fire warning shows up, plus two DC24V power bus.
C. color CRT system uses four-core flat telephone line connection through RS-232 standard interfaces, maximum length should not exceed 15m connector.
◎ Using environment: temperature: 0 ° c ~ + 40 ° c relative humidity ≤ 95%, no condensation
¡Ò main power for power: AC 220V; controller by electron DC24V24Ah sealed lead battery; electric as prepared by the linkage DC24V24Ah sealed lead batteries.
◎ Power consumption ≤ 150W
◎ Dimensions: 580mm×520mm×1873mm
◎ Bus communication distance 1.5 km
◎ Have RS-232, and RS-485 interface