GST-DY-100-power box is a DC24V bulk power output equipment, fire alarm control system that can be used as a coordinated control system of power, as linkage control module and charged device power supply. Power supply unit to the AC 220V as main power, while the built-in DC24V/7Ah sealed lead batteries as backup power supply, switching power supply voltage circuits and maintain electrical floating charge, with output over-current protection, and standby power switch and the perfect preparation of electric power by automatically charging and over-discharge protection. At the same time, the intelligent power supply unit can be kept on the main, electrical and power output status monitoring, master, power failure, fault output, but also has an output voltage, output current display feature to visually observe power box working state.
The main technical indicators are as follows:
◎ Rated output capacity: DC24V, 4A
◎ Using environment: temperature: 0 ° c ~ + 40 ° c relative humidity ≤ 95%, no condensation
¡Ò main power for power: AC 220V, built-in DC24V7Ah sealed lead batteries be electro
◎ Dimensions: 310mm×400mm×115mm
● GST-DY-200-smart power box
GST-DY-200-smart power box is a DC24V bulk power output equipment, fire alarm control system that can be used as a coordinated control system of power, as linkage control module and charged device power supply. Power supply unit to the AC 220V as main power, while the built-in DC24V/24Ah sealed lead batteries as backup power supply, switching power supply voltage circuits and maintain electrical floating charge, with output over-current protection, and standby power switch and perfect automatic charging and prepared by electric over discharge protection. At the same time, the intelligent power supply unit can be kept on the main, electrical and power output status monitoring. When the input voltage is greater than or less than 260V 160V times main power failure; when preparing electrical battery damaged or undervoltage electrical fault when filing; when the output voltage is greater than the 28V or output current greater than 8A times output fault. The power box also has a main electrical voltage, output voltage, output current display feature to visually observe power box working state.
The main technical indicators are as follows:
◎ Rated output capacity: DC24V, 6A
◎ Using environment: temperature: 0 ° c ~ + 40 ° c relative humidity ≤ 95%, no condensation
¡Ò main power for power: AC 220V, built-in DC24V24Ah sealed lead batteries be electro
◎ Dimensions: 500mm×440mm×170mm
● GST-LD-D02-intelligent power-up
GST-LD-D02-intelligent power disk circuit by AC-DC conversion, standby power float control circuit and power control circuit is composed of three parts, specifically for the entire fire control system power supply.
GST-LD-D02-intelligent power up to AC 220V as main power, while the external battery DC24V/24Ah as preparation. Standby power normally accept main power charging, when the site AC power failure, the standby power supply automatically import external supply. Intelligent power supply tray can be on the main electrical faults and alarm output failure, when the input voltage is greater than or less than 160V 260V, reported main power failure; when the output voltage is greater than the 28V or output current greater than 8A, report output. At the same time it also has a battery overcharge and over discharge protection. Power monitor parts for indicating that what is currently being used by all the way to the power supply, AC input voltage and output voltage values, as well as various fault and status display. In a tank fire alarm controller (linkage) as the control core systems, the power-up as a coordinated control system power.
The main technical indicators are as follows:
◎ Output capacity: DC24V, 6A
◎ Using environment: temperature: 0 ° c ~ + 40 ° c humidity: ≤ 95%, no condensation
¡Ò main power for power: AC 220V, built-in DC24V24Ah sealed lead batteries be electro
(VII) fire broadcasting system
• Bus system fire emergency broadcasting system
Fire emergency broadcasting system belongs to the fire alarm control system supporting the use of equipment, through this system you can achieve communication building fire, command related layer evacuation capabilities throughout the fire control system plays an extremely important role.
Bus system fire emergency broadcasting system by the Hudson Bay Company production of fire control centre of the broadcast equipment, with the use of the bus system for fire alarm controller, LD-8305 fire radio module and playback devices. The fire control centre of the broadcast equipment including radio power amplifier, CD recording disc GST-CD type and GST-KZ-deck recording disk, you can set in the Cabinet. Live broadcast using roof and wall-mounted speakers. Use fire radio switch module LD-8305, scene playback device on the bus access controllers, sent by the radio device to the audio broadcast signals, but also through LD-8305 module passive normally open contact (fire broadcasting) and normally closed contact (normal broadcast) added to the playback device, a radio range may be a LD-8305 module to control. The module is equipped with auto-answer feature, when the module actions will generate an alarm signal is fed into the controller generates alerts indicating that normal broadcast and fire broadcasting switch successfully.
Fire emergency broadcasting system playback device can be private or share with the public broadcasting system; when combined with the public broadcasting system, the fire control centre must be fire evacuation level for the speakers and to public broadcasting amplifiers force fire emergency broadcast status while in the fire control centre monitors fire emergency radio amplifiers working state.
Fire broadcasting equipment together with other devices can also be individually assembled in fire control cabinets, equipment power unity by fire control system of power supply.
«More wire fire emergency broadcasting system
Fire emergency broadcasting system belongs to the fire alarm control systemCommission in supporting the use of equipment, through this system you can achieve communication building fire, command related layer evacuation capabilities throughout the fire control system plays an extremely important role.
More wire fire emergency broadcasting system by the Hudson Bay Company production of fire control centre of the broadcast equipment, fire alarm controller, LD-GBFP-100 multiple wire broadcast distribution and live broadcast speaker. The fire control centre of the broadcast equipment including radio power amplifier, CD recording disc GST-CD type and GST-KZ-deck recording disk, you can set in the Cabinet. Live broadcast using roof and wall-mounted speakers. More wire fire broadcasting system's output of broadcasting channels by broadcasting Division to design, each broadcasting a second root partition independent broadcasting channels and live playback devices are connected, the broadcast Division switching control by the fire control centre dedicated multi wire fire broadcast distribution (LD-GBFP-100 type). With this switch, you can complete manually on the broadcasting Division for normal or fire radio switch.
Fire emergency broadcasting system playback device can be private or share with the public broadcasting system; when combined with the public broadcasting system, the fire control centre must be fire evacuation level for the speakers and to public broadcasting amplifiers force fire emergency broadcast status while in the fire control centre monitors fire emergency radio amplifiers working state.
Fire broadcasting equipment together with other devices can also be individually assembled in fire control cabinets, equipment power unity by fire control system of power supply.
(8) fire telephone system
• Bus system fire telephone system
Fire telephone system is a dedicated communication systems for fire, this system can quickly achieve the fire of artificial confirmation, and may hold the fire site and carry out other necessary communications, to direct the fire suppression and recovery work. Telephone system host installation in the control center, the use of embedded installed in the alarm control stringed Cabinet.
The complete bus system fire telephone system consists of a set of fire control centre GST-TS-Z01A-bus system fire phone host and fire alarm controller, on-site LD-8304 module and LD-8312-phone jack and TS-100A fire telephone extension. The system has a design flexible, easy to use and so on.
GST-TS-Z01A-host with recording function, using digital voice memory chips up to record a 30-minute call to fire accident investigation.
LD-8304 module is a direct encoding module, and the fire alarm controller bus connection and need to be connected to the power bus DC24V. To achieve the delivery of telephone voice signal, you need to access the fire phone bus. LD-8304-module has a telephone jack, you can direct telephone extension for bus system.
LD-8312-phone jack and J-SAP-8402 type intelligent coding manual alarm button telephone jack parts are non-coding, direct bus connections with fire telephone constitute non-coded telephone jack, if-module connection with LD-8304, may constitute a coding style phone jack.
Fire telephone system telephone extension can call host without dialing, ringing when the host is the call until the host off-hook or extension to cancel the call; at the same time, the host may call any fixed extension (by fire alarm controller), the extension is ringing when the call until the extension off-hook or cancel the call of fire alarm controller; extension between host allows also can call; telephone jacks can be expanded. Pick a fixed telephone extension or extension plugged LD-8312-Jack and J-SAP-8402-Manual alarm button (including telephone socket) phone jacks are considered extensions caller host. The host calls fixed extension can fire alarm controller starts the appropriate LD-8304 modules allow extension ring. Host and extension, extensions and extension of the call, the call is completed by the host's own control without the need for other controllers.
«More wire fire telephone system
Fire telephone system is a dedicated communication systems for fire, this system can quickly achieve the fire of artificial confirmation, and may hold the fire site and carry out other necessary communications, to direct the fire suppression and recovery work. Telephone system host installation in the control center, the use of embedded installed in the alarm control stringed Cabinet.
Complete wire fire telephone system consists of a set of fire control centre TS-Z02A-multi wire fire phone host and fire alarm controller, LD-8312-phone jack and TS-200A stationary fire telephone extension and TS-200B hand-held fire telephone extension. The system has a design flexible, easy to use and so on.
More wire fire telephone system control core for multiple-line TS-Z02A-fire phone hosts. According to the actual demand, fire phone hosts capacity is not the same. Fire in a multiple-line telephone system, each Department TS-200A type fixed fire Ext. occupy all the way to fire phone hosts, separate two-wire and fire phone hosts connections. LD-8312-fire phone jack can be connected in parallel, parallel, or as many as you like, parallel telephone jack fire phone only occupies one of the host.
Fire telephone system telephone extension can call host without dialing, ringing when the host is the call until the host off-hook or extension to cancel the call; at the same time, the host may call any fixed extension (by fire alarm controller), the extension is ringing when the call until the extension off-hook or cancel the call of fire alarm controller; extension between host allows also can call; telephone jacks can be expanded. Pick a fixed telephone extension or extension plugged LD-8312-type jacks are considered extensions caller host.
More wire fire telephone system host and extension, extensions and extension of the call, the call is completed by the host's own control without the need for other controllers.
(9) gas extinguishing control
● LD-QKP06 type gas fire extinguishing Control Panel
LD-QKP06 gas extinguishing Control Panel is a project of the actual requirements of gas fire extinguishing control interface device, used to drive a gas fire extinguishing system of executive bodies, so as to constitute a complete gas fire control system. This control panel you can directly access fire alarm controller bus, and the company's production of linkage controller or fire alarm controller together with the completion of the gas cylinders, automatic control to control fire extinguishing gas spray.
The control panel can be independent of the linkage controller or fire alarm controller on the connected external device control. The fire alarm controller when an exception occurs, through on-site emergency start/stop-button or the gas fire extinguishing Control Panel on start and stop moving directly to the key realization on gas fire extinguishing equipment of control actions.
LD-QKP06 gas extinguishing Control Panel can be attached spraying led, emergency boot/shutdown action buttons, independent control linkage more wire devices. Extinguishing control panel with external line short circuit and open circuit check alarm function, and have an alternate number line output to ensure that the main gas fire extinguishing equipment maintenance or failure to use an alternate control output reached gas extinguishing purposes.
The main technical indicators are as follows:
◎ Capacity: maximum capacity of control 6 gas fire district (six control unit)
◎ 0s---45s adjustable delay time:
◎ Wire:
A. controller uses two bus connection (polarity signal second bus)
B. steel solenoid valve, pressure switch and spray led multiple wire 2-wire connection
C. emergency boot/shutdown dynamic buttons using multiple wire 3-wire connection
D. xiangqi with sound and light; adopts 2-wire connection
E. exterior with nonpolarized DC24V power
◎ Output: the output tray has 6 points, each group has two DC24V output (main and standby fire)
◎ Using environment: temperature: 0 ° c ~ + 40 ° c relative humidity ≤ 95%, no condensation
◎ Power: DC24V6V (for), you can connect with intelligent power-up or intelligent power box
◎ Monitor power consumption ≤ 10W
◎ Dimensions: 460mm270mm105mm